  manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada105 features 1 easy-to-assemble modules provide thousands of display/control combinations 1 up to 4 incandescent lamps 1 1, 2, 3, or 4-section display 1 transmitted or projected color 1 integral hold-in coil option provides remote released contacts. pull-in coils (flange mount only) enable remote actuation 1 switch guard accessory. change lamps or filters from panel front without tool. remove display screen/ lampholder assembly from 2c200 oper- ator-indicator (or 2f200 indicator). unit is keyed to maintain proper orientation when replacing. use only flange base t-1 3 4 lamps with 2c200 and 2f200 de- vices. lamps and filters order lamps and filters for projected color from page 111. barrier mount display screen (page 115) housing (next page) mounting barrier (next page) switch unit (page 114) mounting barriers attach to either the long or short sides of the housing. they have spring clips which grip the panel. mount- ing barriers also separate display screens to protect against inadvertent operation. multiple units can be attached together in a strip and snapped into a panel slot; or they can be mounted individually. flange mount display screen (page 115) housing (page 113) switch unit (page 114) flange mount units have mounting clips ready-attached to the housing. they can be individually installed or replaced; and enable use of an overlay panel, if desired. groupings can be separated by optional spacing barriers. modules assemble easily all modules are ordered as separate items which snap together for easy as- sembly. pushbuttons
manual switches series 2 pushbuttons switches and indicators 106 honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada barriers on long sides barriers on short sides barrier mount modules barrier mount assemblies are identical in panel appearance. operator-indicator housings have spring clips for attaching switch modules. this feature is not pro- vided with indicator housings. barriers are necessary for mounting. they can be specified for attachment to the long or short side of the housing, as stated in the order guides. barrier mount housing order guide see ``application data'' for typical bailing circuits for coil-equipped modules. tool not required barriers attach on: no. of lamp sockets operator-indicator indicator only long sides of housing 2 (a & c) 2c207 4 (a-d) 2c209 short sides of housing 2 (a & c) 2c201 4 (a-d) 2c203 2f203 mounting barrier order guide for strip mounting, specify one more barrier than the number of units in the group. catalog listings mounting barrier for panel type thickness gray black attach to long sides .06-.19 in. (1,52-4,83 mm) 2b2 2b4 attach to short sides .06-.19 in. (1,52-4,83 mm) 2b1 2b3 note: panels .19 in. (1,52 mm) thick require the .06-.19 in. (1,52-4,83 mm) type barriers.
manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada107 flanges on long sides flange mount modules flange mount assemblies are identical in panel appearance. operator-indicator housings have spring clips for switch modules attachment (not provided with indicator housings). barriers are not required, since the panel mounting clips are ready-attached to flange sides of the housings. however, spacing barriers can be used for color- coding. they also aid in preventing inad- vertent operation of two screens with one push. mounting dimensions on page 114. flange mount housing order guide see ``application data'' for typical bailing circuits for coil-equipped modules. tool not required flanges on: no. of lamp sockets operator- indicator indicator only long sides of housing 2 (a & c) 2c204 4 (a-d) 2c206 2f206 spacing barrier order guide for .06-31 in. (1,5-7,9 mm) thick panels. catalog listings spacing barrier type gray black for long flange housing 2b9 2b18 pushbuttons
manual switches series 2 pushbutton switches and indicators 108 honeywell 1hsensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada switch modules interchangeable type 2d switch modules attach to spring clips on the bottom of operator-indicator housings. there is a wide selection of circuitry, electrical rat- ings, operating actions and terminations. for mounting dimensions, see page 115. electrical rating silver contacts: 30 vdc: 5 amps res. sea level or 50,000 ft, 3 amps ind. sea level, 2.5 amps 50,000 ft. max. inrush, 24 amps. ul and csa rating for basic switch: 5 amps, 125 or 250 vac. gold contacts: 30 vdc: 0.5 amp ind., 1 amp res., sea level and 50,000 ft. max. inrush, 2 amps. sm subminiature multi-spdt switch modules momentary action alternate action sm switch modules offer a choice of two momentary action styles, one with a pro- nounced touch-feedback, the other with low operating force for rapid repeat ac- tuation. also available with alternate- action and combination momentary/ alternate action modules. extra length turret solder terminals. sm switch module order guide momentary action alternate action touch-feedback type low force type no. of spdt circuits silver contacts silver contacts 1 2d100 2d118 2 2d2 2d26 4 2d9 2d33 v3 compact spdt/dpdt switch modules v3 switch modules have screw terminals with lockwashers. quick-connect termi- nals (not shown) are also available. when used with short-flange operator indica- tors, add spacing barriers to prevent interference. electrical rating 30 vdc: 10 amps ind.* sea level, 6 amps ind.,* 50,000 ft. motor load, 6 amps.** ul and csa rating for basic switch: 10 amps, 1 3 hp, 125 or 250 vac; 1 2 amp, 125 vdc; 1 4 amp, 250 vdc. * inductive currents in accordance with an3179. ** motor load rating based on starting current. v3 switch module order guide no. of spdt circuits momentary action 1 2d70 2 2d72
manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada109 one-piece display screen options single-section these translucent solid color display screens are single-section/one piece construction single-section/ one-piece screens order guide colors standard red 2a1 yellow 2a2 green 2a3 white 2a5 three-piece display screen options single-section these screens have transparent colored or colorless caps, transparent colorless legend inserts and translucent colored bases. single-section/three-piece screens order guide colorless color caps red 2a81 yellow 2a82 green 2a85 white 2a70 amber 2A114 note: add l to catalog listing if button is to be legended. silicone rubber baffles prevent light spillage from one section to another. screen caps and legend inserts are transparent colorless. bases are translucent colored. for more information on 2, 3, and 4-section display screens, contact the micro switch application center. pushbuttons
manual switches series 2 pushbutton switches and indicators 110 honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada
manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada111 legend information honeywell micro switch division pro- vides legend service on the inserts sup- plied with three-piece screens only. to specify your needs, add - l to the catalog listings (example: 2a81-l) and use leg- end order sheet (form fo-62308), shown on facing page. reproduce it on your office copier. on any one insert, only one size of type is provided in either black or white. after legending, the insert is assembled to the display screen. the type face used is ``modified gothic''. lamps t-1 3 4 incandescent lamps are available from micro switch in 28 volt versions. use of neon lamps is not recommended. light output is approximately 30% of an incandescent lamp. also, a neon lamp will not illuminate blue or green filters or display screens due to the absence of these colors from the neon light spec- trum. lamp policy the 28 volt lamps are offered as a conve- nience to customers. honeywell micro switch division does not extend any warranty as to such lamps, and cannot guarantee to provide lamps from specific manufacturers. any technical or quality questions regarding such lamps should be directed to the lamp manufacturer. color filters for projected color projected color is achieved by using white buttons and color filters over clear lamps. when lamps are lighted, white button takes on color projected by the filters. filters used with type 2c200 and 2f200 housings (no-tool relamping) slip over lamp sockets in lampholder. screen/legend colors the chart below shows recommended display screen and legend color combi- nations for optimum legibility. legend lettering screen color black white red x green x yellow x amber x x white x lamp order guide rating life/voltage2 catalog base type life in expected listing style no. volts amps hours volts life (hrs.) 2e1 flange 327 28 .040 1000 24.0 7,500 26.0 2,800 30.0 400 2 these are experimental continuous life test results supplied by a lamp manufacturer for reference only. intermittent operation may reduce these figures as much as 50%. ratings are based on median values of current and life. wattage should not exceed 2.4 watts (2 lamps) per switch, for continuous illumination. filter order guide filter style red green amber white* for type 2c200 and 2g12 2g14 2g16 2g17 2f200 housings * has blue tint to compensate for high yellow content of incandescent lamps at low voltages. pushbuttons
manual switches series 2 pushbutton switches and indicators 112 honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada switch guard accessory a hinged cover on the switch guard helps avoid inadvertent operation of the display screen. it is installed in place of the trans- parent slide-on cap furnished with three- piece screen. note: when used with pull- in coil devices, specify the 2c200 oper- ator-indicator housings which have the no-tool relamping feature. barrier mount assembly with guard in- stalled. (can also be used with all flange mount units.) guard requires a ``lift-to-push'' response to operate switch normally. order catalog listing 2h20 key: 0,0 = mm 0.00 = inches
manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada113 mounting dimensions (for reference only) long barrier operator-indicators short barrier operator-indicators short barrier indicators long barrier indicators mounting barriers short long 0,0 = mm key: 0.00 = inches. a panel thickness 1,5/.06 1,5-4,81/.06-.19 4,6/.18 4,8-7,9/.19-.31 length of panel cutout* number of units type of indicator or operator-indicator 1 2 3 4 5 6 7 short mm 36,09 68,00 99,87 131,72 163,60 195,48 227,36 barrier in. 1.421 2.677 3.932 5.186 6.441 7.696 8.951 long mm 30,00 55,78 81,58 106,34 133,12 159,90 184,68 barrier in. 1.181 2.196 3.212 4.226 5.241 6.256 7.271 * nominal dimensions, 0,25 mm/0.10 in. (in 5% of the cases, the cutout will be undersized for the build- up of assembled units and will require enlargement. pushbuttons
manual switches series 2 pushbutton switches and indicators 114 honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada mounting dimensions (for reference only) long flange operator-indicators long flange indicators spacing barriers short long 0,0 = mm key: 0.00 = inches. length of panel cutout* add 4,19 mm/.165 in. to length for each optional spacing barrier used. number of units type of indicator or operator-indicator 1 2 3 4 5 6 7 long mm 27,94 55,75 83,57 111,36 139,17 166,98 194,77 flange in. 1.1 2.195 3.290 4.384 5.479 6.574 7.668 * nominal dimensions, 0,25 mm/0.10 in. (in 5% of the cases, the cutout will be undersized for the build-up of assembled units and will require enlargement.
manual switches series 2 pushbutton switches and indicators honeywell 1sensingandcontrol11-800-537-6945usa1f1-815-235-6847international11-800-737-3360canada115 mounting dimensions (for reference only) sm switch modules v3 switch modules pushbuttons


▲Up To Search▲   

 
Price & Availability of 2A114

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X